ECO18MS2 / ECO30MS3 specifications | ECO30MS4 specifications | ECO36MS4 specifications
| Outdoor Model |
|
ECO18MS2
|
ECO30MS3
|
| Indoor Units Combination |
|
Single
|
Twin
|
Single
|
Twin
|
Triple
|
| Power supply |
|
Ph-V-Hz |
1Ph,220-240V~,50Hz
|
1Ph,220-240V~,50Hz
|
| Cooling |
Capacity |
Btu/h |
7000?12000
|
18000
|
7000?12000
|
16000?19000
|
27000
|
| Capacity |
W |
--
|
5200
|
--
|
--
|
7800
|
| Input |
W |
1000~1200
|
1620
|
1000?1300
|
1800?2200
|
2400
|
| Rated current |
A |
4.5~5.0
|
7.5
|
4.6~6.0
|
8.5~10.0
|
11
|
| EER |
w/w |
--
|
3.21
|
--
|
--
|
3.25
|
| Heating |
Capacity |
Btu/h |
10000~14000
|
21000
|
10000?14000
|
24000?27000
|
30000
|
| Capacity |
W |
--
|
6100
|
|
|
8750
|
| Input |
W |
1050~1250
|
1670
|
1150?1450
|
1950?2300
|
2420
|
| Rated current |
A |
5.0~6.0
|
7.6
|
5.3~6.7
|
9.0~10.6
|
11.2
|
| COP |
w/w |
--
|
3.65
|
--
|
--
|
3.63
|
| Max. input |
W |
2150
|
3100
|
| Max. current |
A |
10.5
|
16.0
|
| Compressor |
Type |
|
Rotary inverter
|
Rotary inverter
|
| Capacity |
Btu/h |
19277
|
22000
|
| Input |
W |
1610
|
1630
|
| Rated current(RLA) |
A |
8.1
|
8.4
|
| Locked rotor Amp(LRA) |
A |
50
|
41
|
| Outdoor fan motor |
Input |
W |
126/106
|
126/106
|
| Capacitor |
uF |
2.5
|
2.5
|
| Speed |
r/min |
760/600
|
760/600
|
| Outdoor air flow |
m3/h |
2500
|
2500
|
| Outdoor noise level |
dB(A) |
53
|
55
|
| Outdoor unit |
Dimension(W*H*D) |
mm |
845X695X335
|
845X695X335
|
| Packing (W*H*D) |
mm |
965X755X395
|
965X755X395
|
| Net/Gross weight |
Kg |
60/64
|
62/66
|
| Refrigerant type and charge |
g |
R410A,1700
|
R410A, 2100
|
| Design pressure(Hi/Lo) |
MPa |
4.2/2.5
|
4.2/2.5
|
| Refrigerant piping |
Liquid side/ Gas side |
mm(inch) |
2 X 6.35(1/4")/9.53(3/8")
|
3 X 6.35(1/4")/9.53(3/8")
|
| Transfer Connector (9.53?12.7) |
|
2
|
2
|
| Max. refrigerant pipe length |
m |
30m total (20m per indoor unit)
|
45m total (20m per indoor unit)
|
| Max. difference in level |
m |
10(each indoor unit)
|
10(each indoor unit)
|
| Connection wiring |
|
No
|
No
|
| Plug type |
|
No
|
No
|
| Thermostat type |
|
Electronic control
|
Electronic control
|
| Operation temp |
°C |
17-30
|
17-30
|
| Ambient temp |
°C |
0~50(cooling); -15~24(heating)
|
0~50(cooling); -15~24(heating)
|
Note: Due to our policy of innovation some specifications may be changed without notification.
These unit contain F-Gas and is govern by F-Gas regulations. All F-Gas must be handle by qualified F-Gas engineers.
ECO18MS2 / ECO30MS3 specifications | ECO30MS4 specifications | ECO36MS4 specifications
| Outdoor Model |
|
ECO30MS4
|
| Indoor Units Combination |
|
Single
|
Twin
|
Triple
|
Quad
|
| Power supply |
|
Ph-V-Hz |
1Ph,220-240V~,50Hz
|
| Cooling |
Capacity |
Btu/h |
7000~18000
|
14000~27000
|
21000~30000
|
27000
|
| Capacity |
W |
--
|
--
|
--
|
7913
|
| Input |
W |
1034~2054
|
1730~2803
|
2634~2977
|
2470
|
| Rated current |
A |
4.7~9.4
|
7.92~12.8
|
12.0~13.5
|
11.2
|
| EER |
w/w |
/
|
/
|
/
|
3.21
|
| Heating |
Capacity |
Btu/h |
8000~18000
|
16000~29000
|
23000~31000
|
30000
|
| Capacity |
W |
--
|
--
|
--
|
8790
|
| Input |
W |
1056~2220
|
1731~3010
|
2439~3155
|
2440
|
| Rated current |
A |
4.8~11.0
|
8.0~13.6
|
11.2~14.4
|
11.1
|
| COP |
w/w |
/
|
/
|
/
|
3.61
|
| Max. input |
W |
4800
|
| Max. current |
A |
21
|
| Compressor |
Type |
|
Rotary inverter
|
| Capacity |
Btu/h |
7130
|
| Input |
W |
2200
|
| Rated current(RLA) |
A |
9.7
|
| Locked rotor Amp(LRA) |
A |
45
|
| Outdoor fan motor |
Input |
W |
144(HIGH)/100(LOW)
|
| Capacitor |
uF |
2.5uF/450V
|
| Speed |
r/min |
780/600
|
| Outdoor air flow |
m3/h |
3500
|
| Outdoor noise level |
dB(A) |
57
|
| Outdoor unit |
Dimension(W*H*D) |
mm |
895X860X330
|
| Packing (W*H*D) |
mm |
1043X915X395
|
| Net/Gross weight |
Kg |
78/82
|
| Refrigerant type and charge |
g |
R410A, 2400
|
| Design pressure(Hi/Lo) |
MPa |
4.2/2.5
|
| Refrigerant piping |
Liquid side/ Gas side |
mm(inch) |
4 x 6.35(1/4")/9.53(3/8")
|
| Transfer Connector (9.53?12.7) |
|
3
|
| Max. refrigerant pipe length |
m |
40m total (20m per indoor unit)
|
| Max. difference in level |
m |
10(each indoor unit)
|
| Connection wiring |
|
No
|
| Plug type |
|
No
|
| Thermostat type |
|
Electronic control
|
| Operation temp |
°C |
17-30
|
| Ambient temp |
°C |
0~50(cooling); -15~24(heating)
|
Note: Due to our policy of innovation some specifications may be changed without notification.
These unit contain F-Gas and is govern by F-Gas regulations. All F-Gas must be handle by qualified F-Gas engineers.
ECO18MS2 / ECO30MS3 specifications | ECO30MS4 specifications | ECO36MS4 specifications
| Outdoor Model |
|
ECO36MS4
|
| Indoor Units Combination |
|
Single
|
Twin
|
Triple
|
Quad
|
| Power supply |
|
Ph-V-Hz |
1Ph,220-240V~,50Hz
|
| Cooling |
Capacity |
Btu/h |
7000~18000
|
14000~36000
|
21000~42000
|
36000
|
| Capacity |
W |
--
|
--
|
--
|
10500
|
| Input |
W |
1334~2384
|
1730~3403
|
2234~3777
|
3450
|
| Rated current |
A |
5.8~7.8
|
7.5~10.7
|
9.7~12.1
|
15.5
|
| EER |
w/w |
/
|
/
|
/
|
3.04
|
| Heating |
Capacity |
Btu/h |
9000~18000
|
16000~37000
|
24000~43000
|
38000
|
| Capacity |
W |
--
|
--
|
--
|
11100
|
| Input |
W |
1656~2520
|
1931~3519
|
2459~3645
|
3380
|
| Rated current |
A |
7.2~11.0
|
9.3~14.9
|
12.9~15.3
|
15.2
|
| COP |
w/w |
/
|
/
|
/
|
3.28
|
| Max. input |
W |
4900
|
| Max. current |
A |
22.5
|
| Compressor |
Type |
|
Rotary inverter
|
| Capacity |
Btu/h |
9860
|
| Input |
W |
3080
|
| Rated current(RLA) |
A |
13.5
|
| Locked rotor Amp(LRA) |
A |
67
|
| Outdoor fan motor |
Input |
W |
320(HIGH)/240(LOW)
|
| Capacitor |
uF |
10uF/450V
|
| Speed |
r/min |
760/620
|
| Outdoor air flow |
m3/h |
5800/4800
|
| Outdoor noise level |
dB(A) |
61
|
| Outdoor unit |
Dimension(W*H*D) |
mm |
990x966x396
|
| Packing (W*H*D) |
mm |
1120X1100X435
|
| Net/Gross weight |
Kg |
86/90
|
| Refrigerant type and charge |
g |
R410A, 2700
|
| Design pressure(Hi/Lo) |
MPa |
4.2/2.5
|
| Refrigerant piping |
Liquid side/ Gas side |
mm(inch) |
4 x 6.35(1/4")/9.53(3/8")
|
| Transfer Connector (9.53?12.7) |
|
4
|
| Max. refrigerant pipe length |
m |
20(each indoor unit)
|
| Max. difference in level |
m |
10(each indoor unit)
|
| Connection wiring |
|
No
|
| Plug type |
|
No
|
| Thermostat type |
|
Electronic control
|
| Operation temp |
°C |
17-30
|
| Ambient temp |
°C |
0~50(cooling); -15~24(heating)
|
Note: Due to our policy of innovation some specifications may be changed without notification.